ISO 9001:2015 · ISO 22000:2018 · ISO 14001:2015🛒 Online Store ↗
ZEEL PRODUCT Z logoZEEL PRODUCT®ZEELCHEM® · Water Treatment Chemicals
Get a Quote
ZEELCHEM® process chemicals

Cooling Water & Cooling Tower Chemicals

Cooling water chemicals control the four problems of every cooling system – scale, corrosion, microbiological growth (biofilm) and fouling. A complete cooling tower programme combines a scale and corrosion inhibitor, a polymer dispersant, an oxidizing biocide and a non-oxidizing biocide, adjusted to the make-up water and cycles of concentration.

Overview

Cooling water chemicals control the four problems of every cooling system – scale, corrosion, microbiological growth (biofilm) and fouling. A complete cooling tower programme combines a scale and corrosion inhibitor, a polymer dispersant, an oxidizing biocide and a non-oxidizing biocide, adjusted to the make-up water and cycles of concentration.

This is one of the largest ZEELCHEM® product categories, because cooling systems face scale, corrosion, microbiological growth, biofilm and fouling all at once. We make the core actives (polymers, phosphonates, biocides) ourselves, so we can tailor cooling tower formulations for HVAC, power, steel, refinery, petrochemical, pharma and food plants – and help you run more cycles with less water.

Cooling Water & Cooling Tower Chemicals – product range

Product rangeMain chemical typeControlsApplication
Cooling Scale InhibitorHEDP / DTPMP / polymerCalcium & mineral scaleCooling towers
Scale + Corrosion InhibitorPhosphonate + polymer + inhibitorScale + corrosionOpen cooling systems
Polymer DispersantPAA / AA-AMPS / HPMASuspended depositsCooling towers
Corrosion Inhibitor – Mild SteelPhosphonate / azole / polymerSteel corrosionCooling systems
Copper / Brass Corrosion InhibitorBTA / TTA chemistryCopper corrosionChillers / heat exchangers
Oxidizing BiocideChlorine / bromine basedAlgae / bacteriaCooling towers
Non-Oxidizing BiocideCMIT/MIT, DBNPA, glutaraldehydeBacteria / fungi / slimeCooling systems
Algae Control ChemicalAlgaecideAlgaeCooling towers
Bio-dispersantSpeciality polymer / surfactantBiofilm / slimeCooling towers
Oil DispersantSpeciality dispersantOil contaminationRefineries / petrochemical
Silica Control ChemicalSpeciality polymerSilica depositionHigh-silica water
Closed Loop InhibitorNitrite / molybdate / azoleCorrosionChilled water
Chiller ChemicalCorrosion + scale inhibitorCorrosion / scaleHVAC / chillers
pH / Alkalinity ControlAcid / alkali formulationpH / alkalinityCooling tower
Cooling Tower CleanerAcid / alkaline cleanerDeposits / foulingPeriodic cleaning

Each programme is selected to your water analysis and system design. Ask for a free technical recommendation.

01

Cooling Scale Inhibitor

Calcium & mineral scale – HEDP / DTPMP / polymer.

02

Scale + Corrosion Inhibitor

Scale + corrosion – Phosphonate + polymer + inhibitor.

03

Polymer Dispersant

Suspended deposits – PAA / AA-AMPS / HPMA.

04

Corrosion Inhibitor – Mild Steel

Steel corrosion – Phosphonate / azole / polymer.

05

Copper / Brass Corrosion Inhibitor

Copper corrosion – BTA / TTA chemistry.

06

Oxidizing Biocide

Algae / bacteria – Chlorine / bromine based.

07

Non-Oxidizing Biocide

Bacteria / fungi / slime – CMIT/MIT, DBNPA, glutaraldehyde.

08

Algae Control Chemical

Algae – Algaecide.

09

Bio-dispersant

Biofilm / slime – Speciality polymer / surfactant.

10

Oil Dispersant

Oil contamination – Speciality dispersant.

11

Silica Control Chemical

Silica deposition – Speciality polymer.

12

Closed Loop Inhibitor

Corrosion – Nitrite / molybdate / azole.

13

Chiller Chemical

Corrosion / scale – Corrosion + scale inhibitor.

14

pH / Alkalinity Control

pH / alkalinity – Acid / alkali formulation.

15

Cooling Tower Cleaner

Deposits / fouling – Acid / alkaline cleaner.

Frequently asked questions

Which chemicals are used in cooling towers?

Cooling towers typically use a scale and corrosion inhibitor (phosphonates such as HEDP/PBTC with polymers such as PAA or AA/AMPS), an oxidizing biocide (chlorine/bromine), a non-oxidizing biocide (CIT/MIT, glutaraldehyde) and a bio-dispersant.

How do I stop scale in a cooling tower?

Use a threshold scale inhibitor and dispersant matched to your water, control cycles of concentration, maintain pH and bleed-off, and monitor with regular water analysis.

Why are two biocides used in a cooling tower?

Alternating an oxidizing and a non-oxidizing biocide prevents microbes from adapting and gives better control of biofilm and Legionella risk.

Can you design a cooling tower programme for my plant?

Yes. Send your make-up water analysis and system details; our team will recommend a ZEELCHEM® programme and dosage.

Also searched as

cooling tower chemicalscooling water treatment chemicals Indiacooling tower scale inhibitorcooling tower biocidecooling tower chemicals Vadodara Gujarat

Key ZEELCHEM™ actives for this programme

HEDP 60

HEDP 60, ZEELCHEM™ 101, is 1-Hydroxyethylidene-1,1-Diphosphonic Acid – an organophosphonate scale and corrosion inhibitor…

CAS 2809-21-4Phosphonates

PBTC 50

PBTC 50, ZEELCHEM™ 121, is 2-Phosphonobutane-1,2,4-Tricarboxylic Acid – a low-phosphorus phosphonate with superior calcium…

CAS 37971-36-1Phosphonates
Fast quotation

Need a price or TDS / MSDS / COA?

Share your product, quantity and delivery location. Our technical sales team replies within business hours with price, availability and documents.