Quick answer: Key water treatment polymer terms: threshold inhibition (scale prevention at mg/L doses), dispersion (keeping particles suspended), cycles of concentration (make-up ÷ blowdown) and LSI (pH − pHs, positive means scaling). They are defined below.

Threshold inhibition

Prevention of scale by a sub-stoichiometric dose of inhibitor (mg/L), far below the amount needed to chelate the scaling ions.

Crystal modification

Distortion of a scale crystal's lattice by adsorbed polymer, producing soft, non-adherent deposits.

Dispersion

Keeping fine solid particles suspended by giving them like charges or a steric barrier, so they do not agglomerate or settle.

Cycles of concentration (COC)

Ratio of dissolved solids in cooling-tower water to those in make-up water; equals make-up ÷ blowdown.

Blowdown

Water deliberately drained from a cooling tower or boiler to limit dissolved-solids concentration.

Langelier Saturation Index (LSI)

Indicator of calcium carbonate scaling tendency: LSI = pH − pHs. Positive values mean scale-forming water.

Ryznar Stability Index (RSI)

Empirical index of scaling or corrosion tendency: RSI = 2pHs − pH. Values below 6 indicate scaling.

Polyacrylic acid (PAA)

Homopolymer of acrylic acid; low MW grades are scale inhibitors and dispersants.

HPMA

Hydrolysed polymaleic anhydride; very low MW, high-charge polymer for high-temperature scale control.

AMPS

2-Acrylamido-2-methylpropane sulphonic acid; sulphonated monomer that gives calcium tolerance.

Terpolymer

Polymer made from three monomers, combining carboxylate, sulphonate and nonionic functions.

Calcium tolerance

Ability of a polymer to stay soluble and active in high-calcium water without precipitating.

Phosphonate

Organophosphorus scale inhibitor such as HEDP, ATMP or PBTC, often blended with polymers.

Antiscalant

Chemical blend dosed to RO/NF feed water to prevent scaling on membranes.

Deflocculant

Additive that reduces the viscosity of clay or mineral slurries by dispersing particles.

Solid content

Non-volatile fraction of a polymer solution, used as a measure of active matter.

Bromine value

Measure of residual unsaturation (double bonds) in HPMA; lower means more complete polymerisation.

Zinc stabilisation

Keeping zinc ions soluble at cooling-water pH so they remain available as a cathodic corrosion inhibitor.

Static jar test

Laboratory test where supersaturated water with inhibitor is held at temperature and residual calcium is measured to calculate % inhibition.

Molecular weight (Mw)

Average size of polymer chains; scale inhibitors are typically 1,000–10,000 Da.

Need a polymer for your water system?

Share your water analysis and system details. Our technical team will recommend the right ZEELCHEM™ polymer and dosage, and send today's price with TDS, MSDS and COA.