Water treatment glossary
Threshold inhibition
Prevention of scale by a sub-stoichiometric dose of inhibitor (mg/L), far below the amount needed to chelate the scaling ions.
Crystal modification
Distortion of a scale crystal's lattice by adsorbed polymer, producing soft, non-adherent deposits.
Dispersion
Keeping fine solid particles suspended by giving them like charges or a steric barrier, so they do not agglomerate or settle.
Cycles of concentration (COC)
Ratio of dissolved solids in cooling-tower water to those in make-up water; equals make-up ÷ blowdown.
Blowdown
Water deliberately drained from a cooling tower or boiler to limit dissolved-solids concentration.
Langelier Saturation Index (LSI)
Indicator of calcium carbonate scaling tendency: LSI = pH − pHs. Positive values mean scale-forming water.
Ryznar Stability Index (RSI)
Empirical index of scaling or corrosion tendency: RSI = 2pHs − pH. Values below 6 indicate scaling.
Polyacrylic acid (PAA)
Homopolymer of acrylic acid; low MW grades are scale inhibitors and dispersants.
HPMA
Hydrolysed polymaleic anhydride; very low MW, high-charge polymer for high-temperature scale control.
AMPS
2-Acrylamido-2-methylpropane sulphonic acid; sulphonated monomer that gives calcium tolerance.
Terpolymer
Polymer made from three monomers, combining carboxylate, sulphonate and nonionic functions.
Calcium tolerance
Ability of a polymer to stay soluble and active in high-calcium water without precipitating.
Phosphonate
Organophosphorus scale inhibitor such as HEDP, ATMP or PBTC, often blended with polymers.
Antiscalant
Chemical blend dosed to RO/NF feed water to prevent scaling on membranes.
Deflocculant
Additive that reduces the viscosity of clay or mineral slurries by dispersing particles.
Solid content
Non-volatile fraction of a polymer solution, used as a measure of active matter.
Bromine value
Measure of residual unsaturation (double bonds) in HPMA; lower means more complete polymerisation.
Zinc stabilisation
Keeping zinc ions soluble at cooling-water pH so they remain available as a cathodic corrosion inhibitor.
Static jar test
Laboratory test where supersaturated water with inhibitor is held at temperature and residual calcium is measured to calculate % inhibition.
Molecular weight (Mw)
Average size of polymer chains; scale inhibitors are typically 1,000–10,000 Da.
Need a polymer for your water system?
Share your water analysis and system details. Our technical team will recommend the right ZEELCHEM™ polymer and dosage, and send today's price with TDS, MSDS and COA.