Purpose
The static jar (bottle) test is a quick, low-cost way to rank inhibitors and find a starting dose under controlled conditions. It does not replace field trials, but it screens options well.
Calcium carbonate test (typical conditions)
| Parameter | Value |
|---|---|
| Ca²⁺ | 240 mg/L (as Ca), from CaCl₂ |
| HCO₃⁻ | 732 mg/L, from NaHCO₃ |
| pH | Adjust to 8.5–9.0 with borate buffer |
| Temperature / time | 80 °C for 10 h (or 70 °C for 16 h) |
| Inhibitor doses | 0, 2, 4, 6, 8, 10 mg/L (active) |
Calcium phosphate test (typical conditions)
Ca 250 mg/L as CaCO₃, PO₄ 10 mg/L, pH 8.5–9.0, 80 °C, 10–24 h. Measure the remaining soluble phosphate after filtration.
Procedure
- Prepare the anion and cation solutions separately in deionised water.
- Add the inhibitor to the anion solution first, then the cation solution, and mix.
- Adjust the pH and seal the bottles. Include a blank (no inhibitor) and an initial (no heating) bottle.
- Incubate at the test temperature.
- Cool, filter through a 0.45 µm membrane and analyse calcium (EDTA titration) or phosphate (colorimetric).
Calculation
% Inhibition = (Ct − Cb) ÷ (C0 − Cb) × 100, where Ct is the soluble ion in the treated sample, Cb in the blank, and C0 the initial value.
Interpreting results
- Plot % inhibition against dose. The plateau shows the minimum effective dose.
- Compare products on an equal active basis.
- Check for turbidity at high dose, which signals polymer precipitation.
Typical outcomes: PAA and HPMA excel in the carbonate test, while AA/AMPS and terpolymer lead in the phosphate test.
FAQ
Is a jar test enough to choose a product?
It is a good screen, but confirm with field monitoring or dynamic tests.
Why filter through 0.45 µm?
To separate precipitated scale from dissolved ions.
Which standard methods exist?
Several national and industry standards describe similar static tests. Conditions vary, so compare products in the same test.