How it works

Defoamer dosage formulas

SituationFormula
Continuous flow, ppmkg/h = flow (m³/h) × density (kg/L) × ppm ÷ 1,000
Continuous flow, %kg/h = flow (m³/h) × density × 1,000 × % ÷ 100
Batch, %kg = batch (L) × density × % ÷ 100
Batch, ppmkg = batch (L) × density × ppm ÷ 1,000,000
Bath, g/Lkg = volume (L) × g/L ÷ 1,000
Pump settingL/h ≈ defoamer kg/h × (1 + dilution parts)

Example: an ETP treating 50 m³/h at 20 ppm uses 50 × 1.0 × 20 ÷ 1,000 = 1.0 kg/h of ZEELCHEM™ DF — 24 kg/day. Diluted 1:10, set the pump to about 11 L/h. Read the full defoamer dosage guide.

FAQ

How do I calculate defoamer dosage?

For continuous flow: defoamer (kg/h) = flow (m³/h) × density (t/m³) × dose (ppm) ÷ 1,000. For a batch: defoamer (kg) = batch mass (kg) × dose (%) ÷ 100. The calculator does both.

What is a typical defoamer dose?

Silicone emulsion defoamers such as ZEELCHEM™ DF often work at about 10–200 ppm; non-silicone defoamers such as ZEELCHEM™ NDF at about 0.05–0.5 % of a formulation. Always confirm by trial.

How do I set my dosing pump?

If you dilute the defoamer 1:x with water, the pump must deliver the defoamer rate × (1 + x). For example 1 kg/h diluted 1:10 needs about 11 L/h.

Is ppm the same as g/m³?

For water and dilute aqueous systems, yes — 1 ppm ≈ 1 g per m³ ≈ 1 mg per litre.